Available in three configurations, 150W, 80W & 90W
High reliability, high efficiency
Rugged lightweight
IP68/1m rating (no cooling fans or vent slots)
Overview
The MN101 AC/DC power converter is designed for demanding military use. Performing up to its maximum output load of 150W. The unit has no switches, plug in the cables and let the unit intelligently distribute the right level of power to your devices. 80W version is available as well as a 90W, non-military standard version.
Is the perfect companion with a ML50 DC charger to provide AC power.
AC/DC converter available in 150W, 90W and 80W versions
Technical Data (150W version)
AC Input
Voltage: Nominally 100-240V AC (90-264V AC), 47-63Hz Input current: 1.75A (100V AC) - 0.7 A (240V AC) at 150 W load, 1.37 A (100V AC) – 0.56 A (240V AC) at 120W load Classification: Safety class 1. To be connected to earth Protection: 3.15A fuse. Not replaceable Power factor >0.95
DC Output
Voltage: 24V DC (Other voltages available on request) Minimum load: No minimum load required Startup delay: 2s max Line regulation: 1% max, ±0.5% typical Load regulation: 5% max, ±3% typical Ripple and noise: ±1% pk-pk max Overvoltage protection: 112-132%, recycle input reset Overload protection: 110-150% with auto recovery Short circuit protection: Trip & restart (Hiccup mode), auto recovery Temperature coefficient: 0.04%/°C Efficiency: 88% typical.
Approvals
Electrical Safety: EN 60 950-1 EMC: Emission and Immunity: MIL-STD-461, EN 55022, EN 61000-3, EN61000-4 Environmental endurance: MIL-STD-810 For complete technical specification on this product, please contact us.
Input cable
1m 3G0.75mm² rubber cable with CEE 7/7 outlet plug. Other lengths and plugs are available on request
Temperature range
Operating: -40ºC to +30ºC: Max output: 24V DC / 6.25A DC / 150W. +30ºC to +55ºC: Max output: 24V DC / 5A DC / 120W. Storage -40ºC to +85ºC
Physical Dimensions
86 x 46 x 210mm (WxHxL) (ex. cables)
Weight
1.25kg (ex. cables)
Accessories
None
Technical Data
AC Input
Voltage: Nominally 100-240V AC (90-264V AC), 47-63Hz Input current: 1.75A (100V AC) - 0.7A (240V AC) at 150W load, 1.37A (100V AC) – 0.56A (240V AC) at 120W load Classification: Safety class 1. To be connected to earth Protection: 3.15A fuse. Not replaceable Power factor >0.95
DC Output
Voltage: 24V DC (Other voltages available on request) Minimum load: No minimum load required Startup delay: 2s max Line regulation: 1% max, ±0.5% typical Load regulation: 5% max, ±3% typical Ripple and noise: ±1% pk-pk max Overvoltage protection: 112-132%, recycle input reset Overload protection: 110-150% with auto recovery Short circuit protection: Trip & restart (Hiccup mode), auto recovery Temperature coefficient: 0.04%/°C Efficiency: 88% typical.
Approvals
Electrical Safety: EN 60 950-1 EMC: Emission and Immunity: MIL-STD-461, EN 55022, EN 61000-3, EN61000-4 Environmental endurance: MIL-STD-810 For complete technical specification on this product, please contact us.
Temperature range
Operating: -40ºC to +30ºC: Max output: 24V DC / 6.25A DC / 150W. +30ºC to +55ºC: Max output: 24V DC / 5A DC / 120W. Storage -40ºC to +85ºC
Physical Dimensions
86 x 46 x 210mm (WxHxL) (ex. cables)
Weight
1.25kg (ex. cables)
Accessories
None.
Input cable
1m 3G0.75mm² rubber cable with CEE 7/7 outlet plug. Other lengths and plugs are available on request
ML50
Charging Duo
The MN101 provides AC power to your ML50 DC charger unit. Perfect for charging your devices both indoor and out.